Residence in Mar Street
Miami, FL


Installation of Auger Cast Piles
Phase 1:

  • # of Piles: 32 piles
  • Diameter: 12″
  • Length: 35′
  • Grout Strength: 5,000 PSI
  • Load Test: No Load Test
  • Additional Services: Not Applicable

Phase 2 – Pool:

  • # of Piles: 19 piles
  • Diameter: 14″
  • Length: 32′
  • Grout Strength: 5,000 PSI
  • Load Test: No Load Test
  • Additional Services: Not Applicable